The integration of the controller results in the following advantages:

  • Very compact design despite integrated controller
  • Easy installation and maintenance free
  • Software for easy setup
  • Internal stroke limitation
  • Adjustable current limit
  • Internal heat protection
  • Industrial interface MODBUS RTU on RS485
  • Adjustable start ramp
  • Adjustable stop ramp
  • Plug & Play solution with iConnect-Box

The integrated control is offered in 6 versions.
All have one MODBUS-RTU system based on RS485:

  • SDB (SINGLE DIRECTION BASIC)
    Simple control to move the actuator up and down. In combination with the iConnect-Box, it develops into a plug-and-play solution. Just plug in and run.

  • SDH (SINGLE DIRECTION HALL)
    Compared to the SDB controller, this controller also emits a Hall signal

  • SDP (SINGLE DIRECTION POSITION)
    This controller also outputs an analog position signal (0V-5V or 0V-10V)

  • SPP (SINGLE POSITION POSITION)
    With this controller, a specific position can be controlled via an analog voltage signal

  • SBS (SINGLE BUS STATUS)
    This controller is operated completely via Modbus-RTU RS485

  • MDO (MULTIPLE DIRECTION OVERRIDE)
    With this controller, up to 8 actuators can easily be operated synchronously

 

FEATURES:

  • Stroke: 50, 100, 150, 200, 250, 300, 350, 400, 500 and 750mm (others on request)
  • Materials:
    Motor and actuator tube are powder coated steel or stainless steel
    Piston rod is stainless steel
  • Protection class: IP66 (standard), harsh environment (according IP68 and IP69)
  • Temperature:
    Operation: -20ºC to +70ºC
    Storage: -40ºC to +70ºC
  • Cable: Cores: 2 x AWG16 + 6 x AWG 26, Ø = 6,8 mm, black jacket, Molex Mini-Fit Jr. 8 pin or similar.
  • Max. static load/Self locking force: 16800N, depending on stroke length for push-applications
  • Duty cycle: Max. 10% or 2 minutes in use followed by 18 minutes rest

 

SPEED AND FORCES

24VDC (28VDC) - Current at maximum load: C-F = 8A, G = 7A, H = 4,5A

 Gear ratio C D E F G H
 Force (dyn. push and pull) [N] 500    1750    2200    3100    4500    4500   
 Speed at maximum load [mm/s] 70 20 17 12 6 4
Max. load limited for stroke length >400mm: 2000N  

12VDC (14VDC)- Current at maximum load: C-F = 16A, G = 14A, H = 9A

 Gear ratio   D E F G H
 Force (dyn. push and pull) [N]   1400    1700    2400    4500    4500   
 Speed at maximum load [mm/s]       14 10 6 3 3,5
Max. load limited for stroke length >400mm: 2000N



SPEED/FORCE (24VDC)

Nopeus voima 24 i50

 FORCE/CURRENT (24VDC)

Nopeus voima 12 i50

SPEED/FORCE (12VDC)

Voima virta 24 i50

FORCE/CURRENT (12VDC)

Voima virta 12 i50
Mitat i50
  EL UL/EN60.601      Harsh environment       Emergency lowering spline     
 Gear ratio: C, D, E, F     stroke + 240*      +15 +14 +23 / +6
 Gear ratio: G, H stroke + 255* +15 +14 +23 / +6


Axial backlash: +/- 0,5mm, generally length tolerance +/- 1mm
* Stroke length >750mm: EL+100mm (on request)

WEIGHT OF THE ACTUATORS:

 Stroke length [mm]      50     100     150     200     250     300     350     400     500     750    
 Weight [kg] 2,1 2,3 2,6 2,8 3,1 3,3 3,6 3,8 4,3 5,6

 

Actual weight may vary depending on model and options selected.

CONNECTING PARTS "MOTOR-SIDE":
HINGE EYE

Saranasilmä1 e50 i

Aluminium
Code: A2M
Maximum static load: 16800N


Stainless steel (316)
Code: C2M
Maximum static load: 16800N

 

 

CONNECTING PART "PISTON-ROD-SIDE":
HINGE EYE

Saranasilmä2 e50 i

Aluminium
Code: A2K
Maximum static load: 16800N


Stainless steel (316)
Code: C2K
Maximum static load: 16800N

 

 

FOR THE FIXATION OF THE EASYE-LINE ACTUATORS WE OFFER THE FOLLOWING BRACKETS:

 
Eel900ba50 2ks

EEL900BA50-2KS

Piston rod side
Max. load: 4500N
Order No.: EEL900BA50-2KS

 
 
 
 
Eel900ba50 2ms

EEL900BA50-2MS

Motor side
Max. load: 4500N
Order No.: EEL900BA50-2MS
 
 
 
 
 

RECOMMENDED MOUNTING METHODS:

  • Do not clamp actuators on tubing
  • Always keep both brackets mounted in the same orientation and ensure to flush mount actuator
  • Brackets must always be able to rotate on axels in mountings

 

Easye asennus

 

PLEASE NOTE

  • Power supply without over-current protection can cause serious damage to the actuator at mechanical end-stop or when actuator is overloaded in another way
  • Radial forces might have an adverse affect on the performance or lead to damage of the actuator
  • Keep piston tube clean
  • Longer cable lengths may cause voltage drop which affects the performance of the actuator
    Max total cable length on 12VDC: 5 meters
  • The dust and water sealing of "harsh environment" actuators might affect their performance
  • All specifications are for 25 ºC ambient – low temperature might affect performance
  • Depending on load and application, nominal and actual stroke length may differ due to internal disc springs not being fully compressed.

EasyE-I installation and programming of the Integrated Controller.

 

EASYE-I:N INSTALLATION
Download PDF file here.

  

INTEGRATED CONTROLLERIN PROGRAMMING